MANUAL & WARRANTY

MANUAL FOR SAFTEY USE AND CARE

CPR CLANCY™ - KD2 MANUAL

IMPORTANT: Please read all official CPR Clancy assembly, cleaning, and maintenance instructions before first use. Ensure you understand correct procedures to prevent product damage or safety risks. IF you require any further information please contact us below.

INTENDED USE AND SAFETY WARNINGS 

  • Professional Training Only: CPR Clancy™ is designed exclusively for first aid, CPR, airway, medication, and emergency response education. It must NEVER be used for real medical treatment or unsupervised play.
  • Child Safety & Small Parts: This product is not a toy and is not suitable for children under 14 years of age. It contains small components that present a choking hazard. Keep out of reach of children. Any training involving children must be conducted under direct adult supervision.
  • Approved Training Materials: Use placebo devices only. Do not use real medications. When simulating bodily fluids (blood, cerebrospinal fluid), use only food-safe, non-toxic training substances.

Modifications: Do not modify or alter the manikin or its components. Damage caused by misuse or unauthorised modification is not covered by the warranty

 

ASSEMBLY AND SET UP

CPR Clancy™ is stored in a back-care-friendly pack-down configuration. Follow these steps to assemble the unit for training:

  1. Place the manikin face down.
  2. Remove the outer chest skin.
  3. Open the chest cavity completely.
  4. Remove the face skin and ensure the nasal training receptacle (NasoPort) is located at the back of the face skin.
  5. Remove the head and neck assembly (attached as one unit).
  6. Position the head and neck into the cavity and close the cavity around it to hold it securely in place.
  7. Reattach the outer chest skin.
  8. Refit the face skin onto the head.
  9. Tilt the head fully backwards to ensure smooth placement of the lung/airway bag.
  10. Use the clear and green introducer to insert a single-use VentilFlow plastic lung/airway bag. Insert until reaching the green section (indicating correct depth) and ensure the bag is not twisted or folded.

Before Training Checklist:

  • Manikin is fully assembled with face skin attached.
  • NasoPort and Ear Cavities (OtoCav) are clean, dry, and ready.
  • A new VentilFlow airway bag is correctly installed and seated.
  • The base cavity is clean and closed.
  • Seals and connectors have been inspected.

 

TRAINING OPERATIONS 

Chest Compressions & Mode Selector

  • Selector Dial: Rotate the green dial on the back of the manikin to select "Adult" or "Child" mode before commencing. Ensure the dial is fully engaged.
  • Technique: Place hands in the centre of the chest and compress straight down with locked arms.
  • Feedback: Audible feedback will indicate adequate compression depth. Avoid angled or off-centred compressions to prevent incorrect feedback and premature wear.

Airway & Ventilations

  • Supported Methods: Head tilt/chin lift, jaw positioning, mouth-to-mask, bag-valve-mask (BVM), Guedel (oropharyngeal) airway, and asthma placebo inhalers.
  • Validation: Visible chest rise confirms correct positioning. If the chest does not rise, reposition the head, check bag placement, or replace the bag if damaged/moist.
  • Requirement: Always ensure a clean, single-use airway bag is installed before conducting any airway training.

Wound & Fluid Simulation Cavities

  • Nasal Cavity (NasoPort): Used for intranasal midazolam and CSF leak training.
  • Ear Cavities (OtoCav): Used for foreign body wash-out and CSF leak demonstration.
  • Abdominal/Chest Wounds: Used for gunshot, impalement, and stabbing scenarios. When simulating bleeding or fluid loss, you MUST use the provided CPR Clancy plastic liner/bag and gloves for hygiene and safety.

 

HYGEINE AND CLEANING PROTOCOLS

Between-Student Protocol

  • Remove and safely dispose of the used VentilFlow airway bag.
  • Wash or sanitise hands.
  • Wipe the nose and mouth area (while the face remains attached) using a mild detergent solution or an approved disinfectant wipe. Allow to remain wet for 30 seconds if using a disinfectant wipe.
  • Dry with a clean cloth or paper towel and air dry briefly.
  • Insert a new VentilFlow airway bag only when the area is completely clean and dry.

End of Day Cleaning: Skin Components

Cleaning Protocol for Face Torso Silicone Skins

  • Wash: Use only warm water (30–40°C) and a mild detergent (like basic dishwashing liquid) using a soft cloth.
  • Rinse: Rinse thoroughly with clean water.
  • Dry: Air dry completely before reassembly.
  • STRICTLY AVOID: Disinfectants, bleach, alcohol-based cleaners, antiseptic wipes, scouring pads, and harsh solvents.

End of Day Cleaning: Simulation Cavities

  • Nasal Cavity & Ear Cavities: Remove inserts (if applicable), flush with warm water, wash with mild detergent, rinse thoroughly, and air dry completely to prevent mold. Reinstall the nasal cavity once dry.
  • Abdominal/Chest Wound Cavities: Dispose of the plastic simulation liner/bag. Clean the cavities with warm water and mild detergent, rinse thoroughly , and ensure completely dry.
  • Base Unit & Storage Cavity: Wipe internal and external surfaces with mild detergent, remove residue with a clean damp cloth, and air dry completely.

 

PACK DOWN STORAGE AND TRANSPORT

Pack Down Procedure

  • Confirm all components (especially face folds, channels, and cavities) are completely clean and dry.
  • Reinstall the NasoPort into the nose cavity.
  • Position the head and neck assembly in the base cavity following the pictures.
  • Attach the chest and two chest overlays to the outside of the unit.
  • Secure all accessories and close the base.
  • Rotate the rear dial to LOCK mode to protect internal mechanisms during transit.

Transport & Environment Warnings

  • Store CPR Clancy™ in the provided carry bag in a cool, dry indoor environment.
  • Remove the head for long-term storage and pack inside the torso.
  • Extreme Temperature Warning: Never leave the manikin in direct sunlight, hot vehicles, or freezing conditions (0°C or below). Rapid temperature changes or extreme heat/cold can cause material embrittlement, warping, cracking, and internal damage without visible warning. Allow a cold manikin to naturally return to room temperature before use. Damage from improper environmental exposure is not covered under warranty.

SUPPORT AND CONTACT INFORMATION

For replacement parts, warranty inquiries, or instructional support, please contact the CPR Clancy team using only approved parts and accessories.

Website: www.cprclancy.com.au

Email: info@cprclancy.com.au 

Copyright: © CPR CLANCY™ | All rights reserved.

 

 

     

    MANUFACTURERS WARRANTY AGAINST DEFECTS

    CPR CLANCY – KD2 TRAINING MANIKIN

    WARRANTY STATEMENT


    CPR Clancy warrants that the CPR CLANCY - KD2 Training Manikin is manufactured to a reasonable standard of quality and is intended for use in CPR and first aid training environments.

     

    This voluntary warranty is provided in addition to, and does not limit, your rights under the Australian Consumer Law (ACL).

     

    Nothing in this warranty excludes, restricts, or modifies any consumer guarantees provided under the Australian Consumer Law.

     

    PRODUCT IDENTIFICATION & WARRANTY PERIOD

    Each CPR CLANCY- KD2 Training Manikin is supplied with a unique serial number or batch identification code for quality control, traceability, and warranty verification purposes. This information must be provided when lodging a warranty claim.

    CPR Clancy provides a two (2) year limited warranty from the date of purchase.

    During this period, CPR CLANCY will assess products that are found to have defects in materials or workmanship under normal and intended training use.

    If a warranty claim is accepted, CPR CLANCY will, at its digression: :

    • repair the product; or
    • replace the product or affected component; or
    • provide an equivalent solution where repair or replacement is not practical.

     

    Any repair or replacement does not extend the original warranty period or create a new warranty term.

    WARRANTY CONDITIONS

     

    This voluntary warranty applies only where the CPR CLANCY -KD2 Training Manikin has been:

    • used in accordance with its intended purpose
    • maintained in a reasonable and appropriate condition
    • not modified, altered, or tampered with by unauthorised persons
    • not subjected to misuse, neglect, or damage outside normal training use

     

    Users are required to follow all supplied care, use, and maintenance instructions provided by CPR Clancy. Failure to follow these instructions may result in damage that is not covered under this voluntary warranty.

    CARE, USE AND ENVIRONMENTAL LIMITATIONS

     

    To ensure proper performance and longevity of the CPR CLANCY- KD2 Training Manikin, reasonable care must be taken in storage, transport, and use.

     

    The CPR CLANCY -KD2 Training Manikin should not be:

    • left in enclosed hot environments (including vehicles or direct sunlight for extended periods)
    • exposed to excessive heat, flame, or high-temperature sources
    • exposed to excessive moisture, flooding, or immersion in water unless specifically designed for such use
    • cleaned with harsh chemicals, solvents, or abrasive cleaning agents not recommended by CPR Clancy
    • subjected to rough handling, crushing, or impact outside normal training use
    • stored in conditions that may cause deformation, material breakdown, or component damage
    • exposed to freezing temperatures (0°C or below) for prolonged periods
    • stored in unheated environments where freezing may occur (including sheds, vehicles, or outdoor storage areas)
    • used immediately after exposure to cold conditions without allowing gradual return to room temperature
    • subjected to rapid heating methods (including heaters, hot water, or direct heat sources) to thaw or restore flexibility

    Cold exposure may result in:

    • temporary or permanent stiffening of silicone or flexible components
    • increased brittleness of plastic parts
    • reduced seal performance in connectors or internal systems
    • potential cracking or material fatigue over time

    Failure to follow these care and environmental guidelines may result in damage that is not covered under this voluntary warranty.

    WHAT THIS WARRANTY DOES NOT COVER

     

    This voluntary warranty does not cover:

    • normal wear and tear from regular training use
    • damage caused by improper assembly, handling, storage, or transport
    • unauthorised repairs or modifications
    • use outside intended CPR and first aid training applications
    • consumable or replaceable components subject to routine degradation

     

    CUSTOMER REMEDY

     

    Where a defect is confirmed under this voluntary warranty, CPR Clancy will provide a remedy that is fair and reasonable in the circumstances.

    Where required under the Australian Consumer Law, reasonable costs associated with return of goods may be covered or reimbursed.

     

    AUSTRALIAN CONSUMER LAW

     

    Our goods come with guarantees that cannot be excluded under the Australian Consumer Law.

    You are entitled to a replacement or refund for a major failure and compensation for reasonably foreseeable loss or damage.

    You are also entitled to have goods repaired or replaced if they fail to meet acceptable quality standards and the failure does not amount to a major failure.

     

    WARRANTY SUPPORT

     

    For warranty enquiries or service requests:

    Email: info@cprclancy.com.au
    Website:
    https://cprclancy.com.au

    © CPR Clancy™ | All rights reserved

    CPR Clancy will assess warranty claims in accordance with applicable consumer law and internal quality procedures.